Furnace
Amana Furnace error codes
52 codes across 4 model families. Start with your model number, because Amana reuses the same numbers for different faults on different boards.
Amana shares code tables with other brands
Amana heating and cooling is built on Goodman control platforms, so Goodman model families and code tables apply.
Find your model family
The model number is on the data plate, usually on the side or back of the unit or behind the service panel. It usually starts with the letters or numbers in the name below.
This AMVM96 / ACVM96 unit runs the same Goodman control board, so its codes are published once under Goodman instead of repeated here. The faults, the checks and the parts are the same because the hardware is.
| Code | What it means | How urgent |
|---|---|---|
| E0 | Lockout after too many ignition retries | Critical |
| E1 | Low stage pressure switch stuck closed at start of heat | High |
| E2 | Low stage pressure switch stuck open | Critical |
| E3 | Open high limit switch | High |
| E4 | Flame detected when no flame should be present | Critical |
| E5 | Open low voltage fuse | High |
| E6 | Low flame signal | High |
| E7 | Igniter fault or improper grounding | High |
| E8 | High stage pressure switch stuck closed at start of heat | High |
| E9 | High stage pressure switch stuck open | High |
| EA | Reversed 115 volt polarity | High |
| EC | Inducer motor overcurrent fault | High |
| EF | Auxiliary input open | Low |
| Ed | Rollout switch open | Critical |
| b0 | Blower motor not running | High |
| b1 | Blower communication error | High |
| b2 | Blower horsepower mismatch | High |
| b3 | Blower motor running in power, temperature or speed limit | High |
| b4 | Blower motor current trip or lost rotor | High |
| b5 | Blower motor locked rotor | High |
| b6 | Blower motor voltage or over temperature trip | High |
| b7 | Incomplete parameters sent to motor | High |
| b9 | Low indoor airflow | High |
| d0 | Data not yet on network | Moderate |
| d4 | Invalid memory card data | High |
| IF | Internal control fault | High |
AMV / GCH / GDS
Goodman, Amana and Daikin legacy furnace flash codes (GMV, GMH, GMS, GMN series)
1980s-2000s · 9 codes
This AMV / GCH / GDS unit runs the same Goodman control board, so its codes are published once under Goodman instead of repeated here. The faults, the checks and the parts are the same because the hardware is.
One shared control table covers the whole legacy group, so these series are listed together. Amana units in the GMN, GMP and GMT group stop at 5 flashes and those in the GDS, GHS, GMS and GKS group stop at 7, so the higher codes do not apply to every Amana in this group. Each code page states which series it covers.
| Code | What it means | How urgent |
|---|---|---|
| 1 flash | Lockout after too many ignition tries | Critical |
| 2 flashes | Pressure switch stuck closed | High |
| 3 flashes | Pressure switch stuck open | Critical |
| 4 flashes | High limit switch open | High |
| 5 flashes | Flame detected when no flame should be present | Critical |
| 6 flashes | Rollout switch open | Critical |
| 7 flashes | Low flame signal | High |
| 8 flashes | Igniter fault or bad grounding | High |
| 9 flashes | High stage pressure switch stuck open | High |
This APG13 unit runs the same Goodman control board, so its codes are published once under Goodman instead of repeated here. The faults, the checks and the parts are the same because the hardware is.
One LED counter is shared between the gas section and the cooling section, so furnace and AC codes cannot be separated.
| Code | What it means | How urgent |
|---|---|---|
| 1 flash | Ignition failure, rollout open, or auxiliary limit open | Critical |
| 2 flashes | Open end centrifugal switch | High |
| 3 flashes | Closed end centrifugal switch with no combustion motor | High |
| 4 flashes | Open high limit switch | High |
| 5 flashes | Flame detected when no flame should be present | Critical |
| 6 flashes | Compressor time delay or short cycle timer | Moderate |
| 7 flashes | Limit opened five times in the same call for heat | High |
| 8 flashes | Indoor or outdoor thermostat open, cooling only | Low |
| 9 flashes | Heat pump or loss of charge switch open, cooling only | High |
This AMSS9 / ACSS9 unit runs the same Goodman control board, so its codes are published once under Goodman instead of repeated here. The faults, the checks and the parts are the same because the hardware is.
A Honeywell-platform control with its own wording and its own code assignments. It is not the GMV table.
| Code | What it means | How urgent |
|---|---|---|
| 1 flash | Furnace lockout after 3 ignition retries | Critical |
| 2 flashes | Pressure switch circuit closed | High |
| 3 flashes | Pressure switch circuit not closed | Critical |
| 4 flashes | Primary or auxiliary limit circuit open | High |
| 5 flashes | Flame sensed with no call for heat | Critical |
| 6 flashes | Rollout limit open or control module fuse blown | Critical |
| 7 flashes | Flame sense signal low | High |
| 8 flashes | Problem with igniter circuit | High |
Common questions
- How many Amana furnace error codes are documented here?
- 52 codes across 4 model families. Every code page lists what the fault means, the causes, the checks you can safely do yourself, and when it stops being worth resetting the unit.
- How do I read the code on a Amana furnace?
- It depends which board you have. Some Amana furnace families print the code as text, and others blink an LED that you count against a legend printed on the board. Check the table above, because the two are read in completely different ways.
- Which Amana furnace model do I have?
- The model number is on the data plate, usually on the side or back of the unit or behind the service panel. The families on this page are AMVM96 / ACVM96, AMV / GCH / GDS, APG13, AMSS9 / ACSS9. The model number starts with the letters or numbers in that name, which is the only reliable way to pick the right code table.
- Do other brands share Amana furnace codes?
- Amana heating and cooling is built on Goodman control platforms, so Goodman model families and code tables apply.