d4Goodman, Amana, Daikin · GMVM96 · Furnace

Goodman, Amana, Daikin GMVM96 error code d4

Invalid memory card data

Goodman is the platform name, and your unit may not say it

Amana AMVM96 / ACVM96, Daikin GMVM96 platform are the same board with a different badge, so this page covers all of them. The fault, the checks and the parts are identical, which is why there is one page rather than one per brand.

Needs attention soon

Quick answer

On Goodman GMVM96 (2010s), d4 is a fault. It means invalid memory card data. A first thing to check: Memory card from a different model.

Applies to
Goodman GMVM96
Goodman and Amana GMVM96, GMVM97, GCVM96 alphanumeric codes · Furnace · 2010s
Type of code
Fault
Urgency: Needs attention soon
First safe check
Note the model number on the card and confirm it matches the furnace.
Checked

What d4 means on this model

The board found data on the memory card that it does not recognise or cannot use. Usually the wrong card, a card from a different model, or data that was interrupted while being written. The furnace falls back to a default configuration, which may not match the installed equipment.

Symptoms you will notice

  • Code present at power up
  • Furnace runs but settings seem wrong
  • Blower runs at unexpected speeds
  • Installer settings lost after a service visit

Common causes

The code tells you what the control detected, not which part failed. These are the causes we see most often, roughly in order of likelihood:

  • Memory card from a different model
  • Card read failure
  • Write interrupted by a power loss during commissioning
  • Failed control board memory

What you can safely check

These are homeowner-level checks. None of them need you to open a live electrical compartment or work on gas.

  • Note the model number on the card and confirm it matches the furnace.
  • Record any installer settings before the card is removed.

Do not do these

  • ×Do not power the furnace off while a card is being written.
  • ×Do not copy settings from a different model. Wrong blower and limit settings can damage the unit.

When to call a technician

Book a technician, do not keep resetting it

This fault will not clear on its own. Every power cycle gives the control one more failed attempt, and repeated attempts are what turn a cheap part replacement into a seized or contaminated system.

  • This is a fuel-burning appliance, so treat anything involving a burner, gas valve or flue as technician work. If you smell gas at any point, leave the property and call the gas utility from outside rather than continuing to diagnose.
  • If the appliance has stopped mid-cycle, is making a noise you have not heard before, or smells burnt, stop reading here and call. Those are symptoms of something the fault code does not describe well enough.

Recording settings is fine. Re-commissioning a furnace is technician work.

What it costs to fix

Parts

Memory card $20 to $60. Control board $250 to $500.

Labor

One to two hours, more if the settings have to be rebuilt.

DIY or technician

Recording settings is fine. Re-commissioning a furnace is technician work.

Typical US part and labor ranges, 2026. They vary by region, model and contractor, so treat them as a planning figure, not a quote.

Scope of this code

Code table
Goodman and Amana GMVM96, GMVM97, GCVM96 alphanumeric codes
Models in scope
Goodman GMVM96, 2010s
Checked
Confirm on your own unit
Find the model number on the data plate, then check this code in the service manual for that model. Manufacturers revise code tables between model years, and a revised board can renumber a fault.