Appliance
Water Heater error codes
Tank and tankless water heater fault codes for gas, electric, and recirculation faults.
47 codes indexed
- 8EBosch · Water Heater
Electrical noise reported on the control board
Therm 250SX, GWH 635ES and 2400E gas tankless
- A2Bosch · Water Heater
Overheat protection tripped, flue gas limiter or overheat fuse
Therm 250SX, GWH 635ES and 2400E gas tankless
- A7Bosch · Water Heater
Hot water temperature sensor fault or out of range
Therm 250SX, GWH 635ES and 2400E gas tankless
- A9Bosch · Water Heater
Outlet temperature sensor not seeing the set temperature
Therm 250SX, GWH 635ES and 2400E gas tankless
- C1Bosch · Water Heater
Fan rotation too low at start-up
Therm 250SX, GWH 635ES and 2400E gas tankless
- C6Bosch · Water Heater
Fan rotation too low during operation
Therm 250SX, GWH 635ES and 2400E gas tankless
- C7Bosch · Water Heater
No fan speed signal from the fan
Therm 250SX, GWH 635ES and 2400E gas tankless
- CABosch · Water Heater
Water flow above the specified maximum
Therm 250SX, GWH 635ES and 2400E gas tankless
- E0Bosch · Water Heater
Control board software or hardware failure
Therm 250SX, GWH 635ES and 2400E gas tankless
- E1Bosch · Water Heater
Over temperature at the hot water sensor
Therm 250SX, GWH 635ES and 2400E gas tankless
- E2Bosch · Water Heater
Inlet temperature sensor fault
Therm 250SX, GWH 635ES and 2400E gas tankless
- E9Bosch · Water Heater
Overheat sensor opened circuit
Therm 250SX, GWH 635ES and 2400E gas tankless
- EABosch · Water Heater
No ionization during the safety time, failed to ignite
Therm 250SX, GWH 635ES and 2400E gas tankless
- ECBosch · Water Heater
Loss of burner flame while burning
Therm 250SX, GWH 635ES and 2400E gas tankless
- F7Bosch · Water Heater
Flame sensed while the unit is in standby
Therm 250SX, GWH 635ES and 2400E gas tankless
- FABosch · Water Heater
Gas valve not closing the gas circuit
Therm 250SX, GWH 635ES and 2400E gas tankless
- HeartbeatBradford White · Water Heater
Thermostat calling for heat, normal operation
Ultra Low NOx D series gas
Not a fault - No lightBradford White · Water Heater
No status light, unit is not powered
Ultra Low NOx D series gas
Not a fault - 1 flash every 2 secondsBradford White · Water Heater
Standby, waiting for a call for heat
Ultra Low NOx D series gas
Not a fault - 2 flashesBradford White · Water Heater
Flue damper test circuit not working, damper stuck open
Ultra Low NOx D series gas
- 3 flashesBradford White · Water Heater
Flue damper test circuit not working, damper not fully open
Ultra Low NOx D series gas
- 4 flashesBradford White · Water Heater
Excessive tank temperature
Ultra Low NOx D series gas
- 5 flashesBradford White · Water Heater
Undesired false pilot flame present
Ultra Low NOx D series gas
- 7 flashesBradford White · Water Heater
Flammable vapour sensor or resettable thermal switch fault
Ultra Low NOx D series gas
- 61 flashBradford White · Water Heater
Failed to light the pilot, unit auto resets
Ultra Low NOx D series gas
- 62 flashesBradford White · Water Heater
Flue damper moved off fully open during the run
Ultra Low NOx D series gas
- 63 flashesBradford White · Water Heater
Pilot flame extinguished, unit auto resets
Ultra Low NOx D series gas
- 64 flashesBradford White · Water Heater
Undesired false pilot flame sensed, unit auto resets
Ultra Low NOx D series gas
- 81 flashBradford White · Water Heater
Flammable vapour sensor out of specification
Ultra Low NOx D series gas
- 82 flashesBradford White · Water Heater
Temperature sensor fault
Ultra Low NOx D series gas
- 83 flashesBradford White · Water Heater
Gas control electronics fault
Ultra Low NOx D series gas
- 84 flashesBradford White · Water Heater
Gas valve fault detected
Ultra Low NOx D series gas
- 91 flashBradford White · Water Heater
Insufficient combustion air detected
Ultra Low NOx D series gas
- 92 flashesBradford White · Water Heater
Combustion chamber temperature sensor out of specification
Ultra Low NOx D series gas
- Weak pilot signalBradford White · Water Heater
Weak pilot signal on the last call for heat
Ultra Low NOx D series gas
- 03AO Smith · Water Heater
Dipswitch setting does not match the installation
310 series condensing tankless
- 10AO Smith · Water Heater
Warning for the combustion lockout
310 series condensing tankless
- 11AO Smith · Water Heater
Ignition failure, the burner never lit
310 series condensing tankless
- 12AO Smith · Water Heater
Loss of flame after ignition
310 series condensing tankless
- 32AO Smith · Water Heater
Temperature sensor open or shorted
310 series condensing tankless
- 39AO Smith · Water Heater
Air-fuel ratio rod fault
310 series condensing tankless
- 55AO Smith · Water Heater
Gas valve or valve circuit fault
310 series condensing tankless
- 61AO Smith · Water Heater
Induced draft fan fault
310 series condensing tankless
- 70AO Smith · Water Heater
Control board fault
310 series condensing tankless
- 72AO Smith · Water Heater
False flame detected
310 series condensing tankless
- 74AO Smith · Water Heater
Remote controller communication fault
310 series condensing tankless
- 99AO Smith · Water Heater
Incomplete combustion, unit locked out
310 series condensing tankless
Pick your brand, then your model family
47 codes across 3 model families. The model family matters, because two water heater models from the same brand can read the same number as two different faults.
Bosch
16 codesCondensing gas tankless platform with a condensing heat exchanger, an induction fan and a flue gas limiter. Four of its codes, A2, A7, A9 and C1, mean something completely different on the Greentherm T9000 platform, and the gas pressure ranges published for it differ from the T9000 ranges, so the code has to be read against the model family rather than as a Bosch code.
Bradford White
19 codesUltra Low NOx D series gas
19 codesAtmospheric gas water heater with a flue damper and a Honeywell WV4472 electronic gas control, which reports faults as a counted LED flash with a three second pause between repeats. The damper codes have no equivalent on units that do not have one, and the codes are not shared with the condensing platforms of other brands.
AO Smith
12 codes310 series condensing tankless
12 codesSealed combustion condensing unit available as direct vent, indoor and outdoor versions. The same two-digit fault numbers apply across the versions, and the fault appears on the control board LED and on the remote controller when one is fitted.