7 flashesBradford White · Ultra Low NOx D series gas · Water Heater

Bradford White Ultra Low NOx D series gas error code 7 flashes

Flammable vapour sensor or resettable thermal switch fault

Stop using it
Also written as seven flashes, 07

Quick answer

On Bradford White Ultra Low NOx D series gas, 7 flashes is a fault. It means flammable vapour sensor or resettable thermal switch fault. A first thing to check: Flammable vapour actually present in the air around the unit.

Applies to
Bradford White Ultra Low NOx D series gas
Bradford White Ultra Low NOx residential D series gas codes · Water Heater
Type of code
Fault
Urgency: Stop using it
First safe check
Think about what has recently been used near the unit. Paint, thinner, solvent, adhesive, and gasoline are the usual triggers.
Checked

What 7 flashes means on this model

The FVIR system has tripped. A flammable vapour sensor and a resettable thermal switch sit in the combustion path, and this code means one of them has locked the burner out because of a vapour present, moisture on the sensor, an extreme temperature, or an open thermal switch.

Symptoms you will notice

  • Seven flashes, then a three second pause
  • Unit will not relight without a reset
  • Fault appears right after a paint job, a solvent job, or a garage refuel
  • Fault appears when a gas appliance is run in an attached garage
  • Restoring power to the burner does not clear it

Common causes

The code tells you what the control detected, not which part failed. These are the causes we see most often, roughly in order of likelihood:

  • Flammable vapour actually present in the air around the unit
  • Flammable vapour sensor exposed to excessive moisture
  • Flammable vapour sensor exposed to extreme ambient temperature
  • Resettable thermal switch open

What you can safely check

These are homeowner-level checks. None of them need you to open a live electrical compartment or work on gas.

  • Think about what has recently been used near the unit. Paint, thinner, solvent, adhesive, and gasoline are the usual triggers.
  • Check whether a vehicle was idled or a fuel-burning tool was run in an attached garage below or beside the unit.
  • Look at the sensor and the thermal switch for visible moisture or condensation.
  • Confirm the reset procedure for the unit, which on this platform involves interrupting power rather than only cycling the gas control.

Do not do these

  • ×Do not defeat, bypass, or jumper the vapour sensor or the thermal switch. They are the reason this appliance is permitted to be installed where it is.
  • ×Do not reset the unit and keep trying while the vapour source is still present. The lockout is the protection.
  • ×Do not locate or relocate the unit to get around repeated trips, because a unit that trips repeatedly belongs in a different installation.

When to call a technician

Stop using the appliance and call today

This one is a safety limit, not a nuisance. The control is shutting the unit down to prevent damage or a hazard, and it will keep doing that until the underlying cause is fixed. Running it anyway risks the expensive failure it was designed to prevent.

  • This is a fuel-burning appliance, so treat anything involving a burner, gas valve or flue as technician work. If you smell gas at any point, leave the property and call the gas utility from outside rather than continuing to diagnose.
  • If the appliance has stopped mid-cycle, is making a noise you have not heard before, or smells burnt, stop reading here and call. Those are symptoms of something the fault code does not describe well enough.

Identifying the vapour source is something a homeowner can do. Testing and replacing the sensor or the switch is a licensed technician job, because it is a safety device.

What it costs to fix

Parts

Flammable vapour sensor $80 to $200. Resettable thermal switch $30 to $90.

Labor

One to two hours to test and replace the sensor or the thermal switch, plus time to find the vapour source.

DIY or technician

Identifying the vapour source is something a homeowner can do. Testing and replacing the sensor or the switch is a licensed technician job, because it is a safety device.

Typical US part and labor ranges, 2026. They vary by region, model and contractor, so treat them as a planning figure, not a quote.

Scope of this code

Code table
Bradford White Ultra Low NOx residential D series gas codes
Models in scope
Bradford White Ultra Low NOx D series gas
Checked
Confirm on your own unit
Find the model number on the data plate, then check this code in the service manual for that model. Manufacturers revise code tables between model years, and a revised board can renumber a fault.