Appliance
Mini Split error codes
Ductless mini split fault codes for indoor and outdoor units.
39 codes indexed
- 11Fujitsu · Mini Split
Serial communication error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 12Fujitsu · Mini Split
Wired remote controller or server room control communication error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 15Fujitsu · Mini Split
Check run unfinished or automatic airflow adjustment error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 18Fujitsu · Mini Split
External communication error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 23Fujitsu · Mini Split
Combination error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 32Fujitsu · Mini Split
Indoor unit PCB model information error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 35Fujitsu · Mini Split
Manual auto switch error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 41Fujitsu · Mini Split
Room temperature sensor error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 42Fujitsu · Mini Split
Indoor heat exchanger middle temperature sensor error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 44Fujitsu · Mini Split
Human sensor error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 51Fujitsu · Mini Split
Indoor unit fan motor error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 62Fujitsu · Mini Split
Outdoor unit main PCB model information or communication error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 63Fujitsu · Mini Split
Inverter error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 64Fujitsu · Mini Split
Active filter or power factor correction circuit error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 65Fujitsu · Mini Split
Trip terminal L error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 71Fujitsu · Mini Split
Discharge temperature sensor error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 73Fujitsu · Mini Split
Outdoor heat exchanger liquid temperature sensor error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 74Fujitsu · Mini Split
Outdoor temperature sensor error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 84Fujitsu · Mini Split
Current sensor error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 94Fujitsu · Mini Split
Trip detection
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 95Fujitsu · Mini Split
Compressor rotor position detection error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 97Fujitsu · Mini Split
Outdoor unit fan motor 1 error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- 99Fujitsu · Mini Split
Four way valve error
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- A1Fujitsu · Mini Split
Discharge temperature error, compressor over-temperature
GENERAL AIRSTAGE KMTC wall split, indoor and outdoor
- Lamp offMitsubishi Electric · Mini Split
No blinking, normal operation
MR SLIM GL series split, indoor and outdoor
Not a fault - 1 blink, 2.5 s OFFMitsubishi Electric · Mini Split
Room temperature thermistor, or indoor outdoor communication error
MR SLIM GL series split, indoor and outdoor
- 2 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Indoor coil thermistor, or outdoor power system
MR SLIM GL series split, indoor and outdoor
- 3 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Serial signal, or one of six outdoor thermistors
MR SLIM GL series split, indoor and outdoor
- 4 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Overcurrent, or compressor startup failure
MR SLIM GL series split, indoor and outdoor
- 5 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Discharge over-temperature, compressor stopped
MR SLIM GL series split, indoor and outdoor
- 6 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
High pressure protection
MR SLIM GL series split, indoor and outdoor
- 7 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Inverter or control board over-temperature
MR SLIM GL series split, indoor and outdoor
- 8 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Outdoor fan motor
MR SLIM GL series split, indoor and outdoor
- 9 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Control board memory, or a shorted power module
MR SLIM GL series split, indoor and outdoor
- 10 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Discharge temperature too low, starved compressor
MR SLIM GL series split, indoor and outdoor
- 11 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Indoor fan motor, or outdoor bus voltage and phase current
MR SLIM GL series split, indoor and outdoor
- 12 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Indoor control board memory
MR SLIM GL series split, indoor and outdoor
- 14 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Closed stop valve, or four way valve and pipe temperature
MR SLIM GL series split, indoor and outdoor
- 16 blinks, 2.5 s OFFMitsubishi Electric · Mini Split
Refrigerant system abnormality, closed valve or air trapped
MR SLIM GL series split, indoor and outdoor
Pick your brand, then your model family
39 codes across 2 model families. The model family matters, because two mini split models from the same brand can read the same number as two different faults.
Fujitsu
24 codesASTG09KMTC and ASTG12KMTC indoor units with AOTG09KMTC and AOTG12KMTC outdoor units on R32. A compatible non-polar wired controller shows the code directly on its display. The supplied wireless controller has no screen and shows the same codes as a flashing pattern on the indoor indicator lamps instead. The service reference gives a separate main PCB, control unit and inverter assembly identification for each of the two capacities, so a board from the wrong capacity is a recognised cause of codes 32 and 62.
Mitsubishi Electric
15 codesMitsubishi Electric splits its equipment across several unrelated control platforms, and the same lamp pattern means different things on each one, so the codes are published per model family rather than for the brand as a whole. The GL series is R410A.
MSZ and MSY indoor units with MUZ cooling only and MUY heating outdoor units on R410A. There is no numeric display: you count blinks of the upper operation indicator lamp on the indoor unit. The same blink count can mean an indoor fault or an outdoor one, and a three second steady hold before the blinking with no beep is what tells the two apart, with a second LED inside the outdoor unit narrowing several outdoor codes to one part.
The matching equipment is published under its own hub
You are in the right place to start, but these codes belong to a different kind of equipment, so we publish them there rather than republishing the same table twice. Follow the link and you are on the canonical page for your unit.
Daikin VRV IV RXTQ-TA / RXTQ-TB
59 codes · under Heat PumpA VRV IV heat pump is a multi split system, so it is the equipment people usually mean when they search mini split error codes, and the same inverter, communication and refrigerant faults are what they are searching for. The codes are published once under Heat Pump rather than twice, and this link is here so you can reach the right table without being sent to an empty page.