Goodman, Amana APG13 error code 7 flashes
Limit opened five times in the same call for heat
Goodman is the platform name, and your unit may not say it
Amana APG13 is the same board with a different badge, so this page covers all of them. The fault, the checks and the parts are identical, which is why there is one page rather than one per brand.
Quick answer
On Goodman APG13 (2000s), 7 flashes is a fault. It means limit opened five times in the same call for heat. A first thing to check: Restricted airflow over the outdoor coil, from dirt, debris or blocked condenser.
- Applies to
- Goodman APG13
- Goodman and Amana APG13, GPG13, APG15 combined furnace and AC flash codes · Furnace · 2000s
- Type of code
- Fault
- Urgency: Needs attention soon
- First safe check
- Look at the outdoor coil. If the fins are packed with cottonwood, grass or a fine grey fuzz of dust, that alone can cause this.
What 7 flashes means on this model
The heat pump has hit its high pressure limit five times in a single call for heat. Five times is the point where the control assumes something is genuinely wrong rather than a momentary condition, and it stops. Cooling often still works, which is why people run the unit in summer without realising the heating side is dead.
Symptoms you will notice
- Heating mode runs briefly, then shuts down
- House is cold even though the thermostat is calling for heat
- Cooling still works normally
- Code appears after several minutes of heating
Common causes
The code tells you what the control detected, not which part failed. These are the causes we see most often, roughly in order of likelihood:
- Restricted airflow over the outdoor coil, from dirt, debris or blocked condenser
- Failed outdoor fan motor, so the coil does not shed heat
- Low or lost refrigerant charge
- Failed high pressure switch
- Stuck reversing valve
- Restricted metering device
What you can safely check
These are homeowner-level checks. None of them need you to open a live electrical compartment or work on gas.
- Look at the outdoor coil. If the fins are packed with cottonwood, grass or a fine grey fuzz of dust, that alone can cause this.
- Confirm the outdoor fan is spinning freely and at speed.
- Check the air filter. A restricted indoor airflow raises head pressure on the heating cycle.
Do not do these
- ×Do not keep calling for heat. Each attempt pushes high pressure into a system that may already be low on charge.
- ×Do not clean the coil with a pressure washer, which bends the fins.
When to call a technician
Book a technician, do not keep resetting it
This fault will not clear on its own. Every power cycle gives the control one more failed attempt, and repeated attempts are what turn a cheap part replacement into a seized or contaminated system.
- This is a fuel-burning appliance, so treat anything involving a burner, gas valve or flue as technician work. If you smell gas at any point, leave the property and call the gas utility from outside rather than continuing to diagnose.
- If the appliance has stopped mid-cycle, is making a noise you have not heard before, or smells burnt, stop reading here and call. Those are symptoms of something the fault code does not describe well enough.
Cleaning a coil and changing a filter are fine. Anything touching refrigerant needs a licensed technician.
What it costs to fix
Parts
Capacitor $25 to $60. High pressure switch $50 to $150. Charge $150 to $400 including labour. Reversing valve $250 to $600.
Labor
Two to four hours depending on what is actually wrong.
DIY or technician
Cleaning a coil and changing a filter are fine. Anything touching refrigerant needs a licensed technician.
Typical US part and labor ranges, 2026. They vary by region, model and contractor, so treat them as a planning figure, not a quote.
Scope of this code
- Code table
- Goodman and Amana APG13, GPG13, APG15 combined furnace and AC flash codes
- Models in scope
- Goodman APG13, 2000s
- Checked
- Confirm on your own unit
- Find the model number on the data plate, then check this code in the service manual for that model. Manufacturers revise code tables between model years, and a revised board can renumber a fault.