Goodman, Amana, Daikin GMVM96 error code E9
High stage pressure switch stuck open
Goodman is the platform name, and your unit may not say it
Amana AMVM96 / ACVM96, Daikin GMVM96 platform are the same board with a different badge, so this page covers all of them. The fault, the checks and the parts are identical, which is why there is one page rather than one per brand.
Quick answer
On Goodman GMVM96 (2010s), E9 is a fault. It means high stage pressure switch stuck open. A first thing to check: High stage pressure switch or its tube fault.
- Applies to
- Goodman GMVM96
- Goodman and Amana GMVM96, GMVM97, GCVM96 alphanumeric codes · Furnace · 2010s
- Type of code
- Fault
- Urgency: Needs attention soon
- First safe check
- Set the thermostat to heat and listen for the inducer to start.
What E9 means on this model
The high stage draft did not prove on this platform. The control asked the inducer to move air for the second stage of gas heat, waited for the pressure switch to confirm it, and got nothing, so it closed the high stage gas valve. Low stage often keeps working, which is why this reads as weak or slow heat instead of a dead furnace.
Symptoms you will notice
- Weak heat, or heat only on the first stage
- Furnace runs but never reaches full capacity
- Code appears on a call for high stage heat
- Longer run time than the same house used to need
Common causes
The code tells you what the control detected, not which part failed. These are the causes we see most often, roughly in order of likelihood:
- High stage pressure switch or its tube fault
- Inducer motor not moving enough air on the high stage setting
- Blocked or restricted flue
- Failing inducer capacitor
- Control board high stage relay fault
What you can safely check
These are homeowner-level checks. None of them need you to open a live electrical compartment or work on gas.
- Set the thermostat to heat and listen for the inducer to start.
- Inspect the high stage pressure tube for cracks, kinks and water.
- Check the vent pipe outside for obstructions.
Do not do these
- ×Do not bypass the pressure switch.
- ×Do not run a furnace that will not reach full capacity as a permanent workaround. Low stage alone will not keep a cold house warm in a hard winter.
When to call a technician
Book a technician, do not keep resetting it
This fault will not clear on its own. Every power cycle gives the control one more failed attempt, and repeated attempts are what turn a cheap part replacement into a seized or contaminated system.
- This is a fuel-burning appliance, so treat anything involving a burner, gas valve or flue as technician work. If you smell gas at any point, leave the property and call the gas utility from outside rather than continuing to diagnose.
- If the appliance has stopped mid-cycle, is making a noise you have not heard before, or smells burnt, stop reading here and call. Those are symptoms of something the fault code does not describe well enough.
Tube inspection and vent checks are fine. A failed pressure switch or board is technician work.
What it costs to fix
Parts
Pressure switch $30 to $90. Inducer capacitor $15 to $40. Inducer motor $150 to $400.
Labor
One to two hours.
DIY or technician
Tube inspection and vent checks are fine. A failed pressure switch or board is technician work.
Typical US part and labor ranges, 2026. They vary by region, model and contractor, so treat them as a planning figure, not a quote.
Scope of this code
- Code table
- Goodman and Amana GMVM96, GMVM97, GCVM96 alphanumeric codes
- Models in scope
- Goodman GMVM96, 2010s
- Checked
- Confirm on your own unit
- Find the model number on the data plate, then check this code in the service manual for that model. Manufacturers revise code tables between model years, and a revised board can renumber a fault.