E1Goodman · GMVC95 · Furnace

Goodman GMVC95 error code E1

Low stage pressure switch stuck closed

Needs attention soon

Quick answer

On Goodman GMVC95 (2000s-2010s), E1 is a fault. It means low stage pressure switch stuck closed. A first thing to check: Pressure switch stuck in the closed position.

Applies to
Goodman GMVC95
Goodman and Amana GMVC95, GCVC95, GCVC96 alphanumeric codes · Furnace · 2000s-2010s
Type of code
Fault
Urgency: Needs attention soon
First safe check
Find the round pressure switch, usually clipped near the burner compartment or on the blower deck, and follow the clear plastic tube attached to it.
Checked

What E1 means on this model

This is the low stage pressure switch reporting venting before ignition. The switch should be closed until the draft is proven and then open as the inducer moves air. Reading venting at the moment the control expects the flue to still be full means the switch or its tube is not behaving, and the burner will not be called for.

Symptoms you will notice

  • Furnace will not fire
  • Short draft blower noise, then a click, then nothing
  • No heat
  • Code returns immediately after a reset

Common causes

The code tells you what the control detected, not which part failed. These are the causes we see most often, roughly in order of likelihood:

  • Pressure switch stuck in the closed position
  • Cracked, pinched or disconnected plastic pressure tube
  • Water or condensation sitting in a low point of that tube
  • Inducer motor spinning too slowly to move enough air to trip the switch
  • Loose connector in the pressure switch circuit

What you can safely check

These are homeowner-level checks. None of them need you to open a live electrical compartment or work on gas.

  • Find the round pressure switch, usually clipped near the burner compartment or on the blower deck, and follow the clear plastic tube attached to it.
  • Inspect the whole length of tube for a crack, a kink, or water pooled in a dip.
  • Watch the squirrel cage on the draft inducer while the furnace calls for heat. It should spin up quickly and evenly.

Do not do these

  • ×Do not tape over, plug, or block the pressure switch. It is the part that stops the furnace releasing gas into a flue that is not moving air.
  • ×Do not run the furnace with the burner compartment open.

When to call a technician

Book a technician, do not keep resetting it

This fault will not clear on its own. Every power cycle gives the control one more failed attempt, and repeated attempts are what turn a cheap part replacement into a seized or contaminated system.

  • This is a fuel-burning appliance, so treat anything involving a burner, gas valve or flue as technician work. If you smell gas at any point, leave the property and call the gas utility from outside rather than continuing to diagnose.
  • If the appliance has stopped mid-cycle, is making a noise you have not heard before, or smells burnt, stop reading here and call. Those are symptoms of something the fault code does not describe well enough.

Replacing a cracked tube and cleaning a blocked condensate drain are fine homeowner work. Replacing the switch is at the edge of it.

What it costs to fix

Parts

Pressure switch $30 to $90. Pressure tube $5 to $20. Inducer capacitor $15 to $40.

Labor

Usually under an hour. Straightforward once the burner compartment is open.

DIY or technician

Replacing a cracked tube and cleaning a blocked condensate drain are fine homeowner work. Replacing the switch is at the edge of it.

Typical US part and labor ranges, 2026. They vary by region, model and contractor, so treat them as a planning figure, not a quote.

Scope of this code

Code table
Goodman and Amana GMVC95, GCVC95, GCVC96 alphanumeric codes
Models in scope
Goodman GMVC95, 2000s-2010s
Checked
Confirm on your own unit
Find the model number on the data plate, then check this code in the service manual for that model. Manufacturers revise code tables between model years, and a revised board can renumber a fault.