Goodman GMVC95 error codes
Goodman and Amana GMVC95, GCVC95, GCVC96 alphanumeric codes. 23 codes.
Check this is your model before you read on
The model number on your data plate should start with GMVC95, GCVC95, GCVC96, AMVC96. Close to the GMVM96 list, but this platform has no rollout code. Some websites quietly copy the GMVM96 table onto these models and that adds a fault they do not have.
Similar to GMVM96 but has no rollout code, which changes the safety story.
The same table applies to amana, Daikin models on the same control platform.
How to read this code
Two character LED display, read directly. Not a blink count.
2000s-2010s. 24 codes on this control platform.
23 fault codes
Every one of these means something is wrong. Ordered by how urgent they are.
b0GoodmanBlower motor not runningb1GoodmanBlower communication errorb2GoodmanBlower horsepower mismatchb3GoodmanBlower running in a protection limitb4GoodmanBlower current trip or lost rotorb5GoodmanBlower motor locked rotorb6GoodmanBlower voltage or over temperature tripb7GoodmanIncomplete parameters sent to motorb9GoodmanLow indoor airflowd0GoodmanData not yet on networkd4GoodmanInvalid memory card dataE0GoodmanLockout after too many ignition retriesE1GoodmanLow stage pressure switch stuck closedE2GoodmanLow stage pressure switch stuck openE3GoodmanOpen high limit switchE4GoodmanFlame detected when no flame should be presentE5GoodmanOpen low voltage fuseE6GoodmanLow flame signalE7GoodmanIgniter fault or improper groundingE8GoodmanHigh stage pressure switch stuck closedE9GoodmanHigh stage pressure switch stuck openEAGoodmanReversed 115 volt polarityIFGoodmanInternal control fault