3 flashesGoodman, Amana · ASX13 · AC

Goodman, Amana ASX13 error code 3 flashes

Compressor short cycling

Goodman is the platform name, and your unit may not say it

Amana ASX13 / ASZ13 is the same board with a different badge, so this page covers all of them. The fault, the checks and the parts are identical, which is why there is one page rather than one per brand.

Needs attention soon

Quick answer

On Goodman ASX13 (2000s-2010s), 3 flashes is a fault. It means compressor short cycling. A first thing to check: Low refrigerant charge or a leak.

Applies to
Goodman ASX13
Goodman and Amana ASX13, ASZ13, ASXC16, ASZC16 air conditioner flash codes · Air Conditioner · 2000s-2010s
Type of code
Fault
Urgency: Needs attention soon
First safe check
Check the capacitor for bulging and the contactor for pitting.
Checked

What 3 flashes means on this model

The compressor is starting and stopping on a cycle much shorter than it should. Either it is losing pressure between starts, it cannot get up to speed, or the control is cutting it off. Sustained short cycling will kill a compressor, so this is worth dealing with even if cooling seems adequate.

Symptoms you will notice

  • Outdoor unit starts and stops every few minutes
  • House never holds set temperature
  • Compressor sounds strained or clicks
  • Code appears on repeated cycles

Common causes

The code tells you what the control detected, not which part failed. These are the causes we see most often, roughly in order of likelihood:

  • Low refrigerant charge or a leak
  • Failed compressor, unable to build pressure
  • Failed capacitor or contactor
  • Failed outdoor fan motor
  • Frozen or restricted metering device
  • Low voltage supply to the outdoor unit

What you can safely check

These are homeowner-level checks. None of them need you to open a live electrical compartment or work on gas.

  • Check the capacitor for bulging and the contactor for pitting.
  • Check the condenser fan spins freely and at speed.
  • Check the outdoor unit breaker voltage at the time of start. A sagging supply will stop a compressor.

Do not do these

  • ×Do not keep resetting the unit. Each short cycle stresses the compressor windings and the contactor.
  • ×Do not add refrigerant as a first step. If the compressor has lost its charge internally, refrigerant will not fix it.

When to call a technician

Book a technician, do not keep resetting it

This fault will not clear on its own. Every power cycle gives the control one more failed attempt, and repeated attempts are what turn a cheap part replacement into a seized or contaminated system.

  • The refrigerant circuit is sealed and legally requires licensed handling. Opening it without certification releases refrigerant and can put the whole system in violation of regulation, so a low-pressure or high-pressure fault on this equipment is a call-out, not a weekend job.
  • If the appliance has stopped mid-cycle, is making a noise you have not heard before, or smells burnt, stop reading here and call. Those are symptoms of something the fault code does not describe well enough.

Capacitor and contactor are reasonable. Compressor work means recovering refrigerant and is licensed.

What it costs to fix

Parts

Capacitor $25 to $60. Contactor $25 to $70. Compressor $900 to $2,000. Charge $150 to $400 including labour.

Labor

Half a day for a compressor.

DIY or technician

Capacitor and contactor are reasonable. Compressor work means recovering refrigerant and is licensed.

Typical US part and labor ranges, 2026. They vary by region, model and contractor, so treat them as a planning figure, not a quote.

Scope of this code

Code table
Goodman and Amana ASX13, ASZ13, ASXC16, ASZC16 air conditioner flash codes
Models in scope
Goodman ASX13, 2000s-2010s
Checked
Confirm on your own unit
Find the model number on the data plate, then check this code in the service manual for that model. Manufacturers revise code tables between model years, and a revised board can renumber a fault.